Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Digit Health ; 9: 20552076231218885, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38053733

RESUMO

Background: Recent technological developments enable big data-driven insights on diurnal changes. This study aimed to describe the trajectory of multiple and advanced parameters using a medical-grade wearable remote patient monitor. Methods: Parameters were monitored for 24 h in 256 ambulatory participants who kept living their normal life. Parameters included heart rate, blood pressure, stroke volume, cardiac index, systemic vascular resistance, blood oxygen saturation, and respiratory rate. Diurnal variations were evaluated, and analyses were stratified based on sex, age, and body mass index. Results: All parameters showed diurnal changes (p < 0.001). Females demonstrated higher heart rate and cardiac index with lower systemic vascular resistance. Obese participants had a higher blood pressure, and lower stroke volume and cardiac index. Systemic vascular resistance was higher among the elderly. Diurnal changes corresponded with awake-sleep hours and differed between sex, age, and body mass index groups. Conclusion: Wearable monitoring platforms could decipher hemodynamic changes in subgroups of individuals, and might help with efforts to provide personalized medicine, pre-symptomatic diagnosis and prevention, and drug development.

2.
Front Physiol ; 14: 1279314, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38033330

RESUMO

Introduction: Body temperature is essential for diagnosing, managing, and following multiple medical conditions. There are several methods and devices to measure body temperature, but most do not allow continuous and prolonged measurement of body temperature. Noninvasive skin temperature sensor combined with a heat flux sensor, also known as the "double sensor" technique, is becoming a valuable and simple method for frequently monitoring body temperature. Methods: Body temperature measurements using the "double sensor" method in a wearable monitoring device were compared with oral and core body temperature measurements using medical grade thermometers, analyzing data from two prospective clinical trials of different clinical scenarios. One study included 45 hospitalized COVID-19 patients in which oral measurements were taken using a hand-held device, and the second included 18 post-cardiac surgery patients in which rectal measurements were taken using a rectal probe. Results: In study 1, Bland-Altman analysis showed a bias of -0.04°C [0.34-(-0.43)°C, 95% LOA] with a correlation of 99.4% (p < 0.001). In study 2, Bland-Altman analysis showed a bias of 0.0°C [0.27-(-0.28)°C, 95% LOA], and the correlation was 99.3% (p < 0.001). In both studies, stratifying patients based on BMI and skin tone showed high accordance in all sub-groups. Discussion: The wearable monitor showed high correlation with oral and core body temperature measurements in different clinical scenarios.

3.
Chron Respir Dis ; 20: 14799731231198865, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37612250

RESUMO

BACKGROUND: Respiratory rate (RR) is used for the diagnosis and management of medical conditions and can predict clinical changes. Heavy workload, understaffing, and errors related to poor recording make it underutilized. Wearable devices may facilitate its use. METHODS: RR measurements using a wearable photoplethysmography-based monitor were compared with medical grade devices in complementary clinical scenarios: Study one included a comparison to a capnograph in 35 healthy volunteers; Study two included a comparison to a ventilator monitor in 18 ventilated patients; and Study three included a comparison to capnograph in 92 COVID-19 patients with active pulmonary disease. Pearson's correlations and Bland-Altman analysis were used to assess the accuracy and agreement between the measurement techniques, including stratification for Body Mass Index (BMI) and skin tone. Statistical significance was set at p ≤ 0.05. RESULTS: High correlation was found in all studies (r = 0.991, 0.884, and 0.888, respectively, p < 0.001 for all). 95% LOA of ±2.3, 1.7-(-1.6), and ±3.9 with a bias of < 0.1 breaths per minute was found in Bland-Altman analysis in studies 1,2, and 3, respectively. In all, high accordance was found in all sub-groups. CONCLUSIONS: RR measurements using the wearable monitor were highly-correlated with medical-grade devices in various clinical settings. TRIAL REGISTRATION: ClinicalTrials.gov, https://clinicaltrials.gov/ct2/show/NCT03603860.


Assuntos
Taxa Respiratória , Dispositivos Eletrônicos Vestíveis , Humanos , Índice de Massa Corporal , Monitorização Fisiológica/métodos
4.
Digit Health ; 9: 20552076231179014, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37312950

RESUMO

Background: Continuous monitoring of ECG, respiratory rate, systolic and diastolic blood pressure, pulse rate, cardiac output, and cardiac index is important in patients with ST-elevation myocardial infarction (STEMI) admitted to the intensive cardiac care unit (ICCU). However, monitoring these parameters in this setting and in these patients using noninvasive, wireless devices has not been conducted so far. We aimed to assess the use of a novel noninvasive continuous monitoring device in STEMI patients admitted to the ICCU. Methods: Participants included STEMI patients that were admitted to the ICCU after primary percutaneous coronary intervention (PPCI). Patients were continuously monitored using a novel wearable chest patch monitor. Results: Fifteen patients with STEMI who underwent PPCI were included in this study. The median age was 52.8 years, the majority were males, and the median body mass index (BMI) was 25.7. Monitoring lasted for 66 ± 16 hours, and included the automatic collection and recording of all vitals, freeing the nursing staff to focus on other tasks. The user experience of nurses as reflected in filled questionnaires showed high satisfaction rates in all aspects. Conclusion: A novel noninvasive, wireless device showed high feasibility in continuously monitoring multiple crucial parameters in STEMI patients admitted to the ICCU after PPCI.

5.
Front Physiol ; 14: 1138647, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37064911

RESUMO

Background: Currently-used tools for early recognition of clinical deterioration have high sensitivity, but with low specificity and are based on infrequent measurements. We aimed to develop a pre-symptomatic and real-time detection and warning tool for potential patients' deterioration based on multi-parameter real-time warning score (MPRT-WS). Methods: A total of more than 2 million measurements were collected, pooled, and analyzed from 521 participants, of which 361 were patients in general wards defined at high-risk for deterioration and 160 were healthy participants allocation as controls. The risk score stratification was based on cutoffs of multiple physiological parameters predefined by a panel of specialists, and included heart rate, blood oxygen saturation (SpO2), respiratory rate, cuffless systolic and diastolic blood pressure (SBP and DBP), body temperature, stroke volume (SV), cardiac output, and systemic vascular resistance (SVR), recorded every 5 min for a period of up to 72 h. The data was used to define the various risk levels of a real-time detection and warning tool, comparing it with the clinically-used National Early Warning Score (NEWS). Results: When comparing risk levels among patients using both tools, 92.6%, 6.1%, and 1.3% of the readings were defined as "Low", "Medium", and "High" risk with NEWS, and 92.9%, 6.4%, and 0.7%, respectively, with MPRT-WS (p = 0.863 between tools). Among the 39 patients that deteriorated, 30 patients received 'High' or 'Urgent' using the MPRT-WS (42.7 ± 49.1 h before they deteriorated), and only 6 received 'High' score using the NEWS. The main abnormal vitals for the MPRT-WS were SpO2, SBP, and SV for the "Urgent" risk level, DBP, SVR, and SBP for the "High" risk level, and DBP, SpO2, and SVR for the "Medium" risk level. Conclusion: As the new detection and warning tool is based on highly-frequent monitoring capabilities, it provides medical teams with timely alerts of pre-symptomatic and real-time deterioration.

6.
PLoS One ; 17(12): e0277618, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36534662

RESUMO

OBJECTIVES: Chest X-ray (CXR) is routinely required for assessing Central Venous Catheter (CVC) tip position after insertion, but there is limited data as to the movement of the tip location during hospitalization. We aimed to assess the migration of Central Venous Catheter (CVC) position, as a significant movement of catheter tip location may challenge some of the daily practice after insertion. DESIGN AND SETTINGS: Retrospective, single-center study, conducted in the Intensive Care and Cardiovascular Intensive Care Units in Tel Aviv Sourasky Medical Center 'Ichilov', Israel, between January and June 2019. PATIENTS: We identified 101 patients with a CVC in the Right Internal Jugular (RIJ) with at least two CXRs during hospitalization. MEASUREMENTS AND RESULTS: For each patient, we measured the CVC tip position below the carina level in the first and all consecutive CXRs. The average initial tip position was 1.52 (±1.9) cm (mean±SD) below the carina. The maximal migration distance from the initial insertion position was 1.9 (±1) cm (mean±SD). During follow-up of 2 to 5 days, 92% of all subject's CVCs remained within the range of the Superior Vena Cava to the top of the right atrium, regardless of the initial positioning. CONCLUSIONS: CVC tip position can migrate significantly during a patient's early hospitalization period regardless of primary location, although for most patients it will remain within a wide range of the top of the right atrium and the middle of the Superior Vena Cava (SVC), if accepted as well-positioned.


Assuntos
Cateterismo Venoso Central , Cateteres Venosos Centrais , Humanos , Veia Cava Superior , Estudos Retrospectivos , Estado Terminal
7.
Front Physiol ; 13: 911544, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35846008

RESUMO

Vital signs obtained by photoplethysmography-based devices might be influenced by subcutaneous fat and skin color. This observational comparison study aimed to test the accuracy of blood pressure (BP) measurements between a photoplethysmography-based device and cuff-based BP device in ambulatory individuals, coming for a routine BP checkup. Systolic BP (SBP) and diastolic BP (DBP) measurements were stratified based on sex, BMI (<25; 25 ≤BMI<30; 30 ≤kg/m2), and skin color (types 1-3 and 4-6 by the Fitzpatrick scale). A total of 1548 measurements were analyzed. Correlations of SBP and DBP between the devices among males/females were between 0.914-0.987 (p < 0.001), and Bland-Altman analysis showed a bias of less than 0.5 mmHg for both sexes. Correlations of SBP and DBP between the devices among BMI groups were between 0.931-0.991 (p < 0.001), and Bland-Altman analysis showed a bias of less than 1 mmHg for all. Correlations of SBP and DBP between the devices among the skin color groups were between 0.936-0.983 (p < 0.001), and Bland-Altman analysis showed a bias of less than 1 mmHg for all. This study shows similar and high agreements between BP measurements obtained using a PPG-based non-invasive cuffless BP device and a cuff-based BP device across sex, BMI, and skin color groups.

8.
Crit Care Explor ; 4(2): e0624, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35128457

RESUMO

OBJECTIVES: Cardiac output (CO) measurements in the ICU are usually based on invasive techniques, which are technically complex and associated with clinical complications. This study aimed to compare CO measurements obtained from a noninvasive photoplethysmography-based device to a pulse contour cardiac output device in ICU patients. DESIGN: Observational, prospective, comparative clinical trial. SETTING: Single-center general ICU. PATIENTS: Patients admitted to the general ICU monitored using a pulse contour cardiac output device as per the decision of the attending physician. INTERVENTIONS: Parallel monitoring of CO using a photoplethysmography-based chest patch device and pulse contour cardiac output while the medical team was blinded to the values obtained by the noninvasive device. MEASUREMENTS AND MAIN RESULTS: Seven patients (69 measurements) were included in the final analysis. Mean CO were 7.3 ± 2.0 L/m and 7.0 ± 1.5 L/m for thermodilution and photoplethysmography, respectively. Bland-Altman showed that the photoplethysmography has a bias of 0.3 L/m with -1.6 and 2.2 L/m 95% limit of agreement (LOA) and a bias of 2.4% with 95% LOA between -25.7% and 30.5% when calculating the percentage of difference from thermodilution. The values obtained by thermodilution and photoplethysmography were highly correlated (r = 0.906). CONCLUSIONS: The tested chest patch device offers a high accuracy for CO compared to data obtained by the pulse contour cardiac output and the thermodilution method in ICU patients. Such devices could offer advanced monitoring capabilities in a variety of clinical settings, without the complications of invasive devices.

9.
J Clin Med ; 12(1)2022 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-36614848

RESUMO

There are no clear guidelines for diuretic administration in heart failure (HF), and reliable markers are needed to tailor treatment. Continuous monitoring of multiple advanced physiological parameters during diuresis may allow better differentiation of patients into subgroups according to their responses. In this study, 29 HF patients were monitored during outpatient intravenous diuresis, using a noninvasive wearable multi-parameter monitor. Analysis of changes in these parameters during the course of diuresis aimed to recognize subgroups with different response patterns. Parameters did not change significantly, however, subgroup analysis of the last quartile of treatment showed significant differences in cardiac output, cardiac index, stroke volume, pulse rate, and systemic vascular resistance according to gender, and in systolic blood pressure according to habitus. Changes in the last quartile could be differentiated using k-means, a technique of unsupervised machine learning. Moreover, patients' responses could be best clustered into four groups. Analysis of baseline parameters showed that two of the clusters differed by baseline parameters, body mass index, and diabetes status. To conclude, we show that physiological changes during diuresis in HF patients can be categorized into subgroups sharing similar response trends, making noninvasive monitoring a potential key to personalized treatment in HF.

10.
J Clin Med ; 10(21)2021 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-34768722

RESUMO

Early detection of influenza may improve responses against outbreaks. This study was part of a clinical study assessing the efficacy of a novel influenza vaccine, aiming to discover distinct, highly predictive patterns of pre-symptomatic illness based on changes in advanced physiological parameters using a novel wearable sensor. Participants were frequently monitored 24 h before and for nine days after the influenza challenge. Viral load was measured daily, and self-reported symptoms were collected twice a day. The Random Forest classifier model was used to classify the participants based on changes in the measured parameters. A total of 116 participants with ~3,400,000 data points were included. Changes in parameters were detected at an early stage of the disease, before the development of symptomatic illness. Heart rate, blood pressure, cardiac output, and systemic vascular resistance showed the greatest changes in the third post-exposure day, correlating with viral load. Applying the classifier model identified participants as flu-positive or negative with an accuracy of 0.81 ± 0.05 two days before major symptoms appeared. Cardiac index and diastolic blood pressure were the leading predicting factors when using data from the first and second day. This study suggests that frequent remote monitoring of advanced physiological parameters may provide early pre-symptomatic detection of flu.

11.
J Clin Med ; 10(18)2021 Sep 17.
Artigo em Inglês | MEDLINE | ID: mdl-34575328

RESUMO

COVID-19 exerts deleterious cardiopulmonary effects, leading to a worse prognosis in the most affected. This retrospective multi-center observational cohort study aimed to analyze the trajectories of key vitals amongst hospitalized COVID-19 patients using a chest-patch wearable providing continuous remote patient monitoring of numerous vital signs. The study was conducted in five COVID-19 isolation units. A total of 492 COVID-19 patients were included in the final analysis. Physiological parameters were measured every 15 min. More than 3 million measurements were collected including heart rate, systolic and diastolic blood pressure, cardiac output, cardiac index, systemic vascular resistance, respiratory rate, blood oxygen saturation, and body temperature. Cardiovascular deterioration appeared early after admission and in parallel with changes in the respiratory parameters, showing a significant difference in trajectories within sub-populations at high risk. Early detection of cardiovascular deterioration of COVID-19 patients is achievable when using frequent remote patient monitoring.

12.
Harefuah ; 160(3): 181-185, 2021 03.
Artigo em Hebraico | MEDLINE | ID: mdl-33749182

RESUMO

INTRODUCTION: Elective clerkships in low income countries have been an integral part of the curriculum in the majority of medical schools worldwide. These programs expose students to global challenges, to a diversity of cultures and healthcare systems, and have been shown to improve medical knowledge, as well as clinical and communication skills. In 2018 and 2019, the Faculty of Medicine at the Technion, in cooperation with the Department for Infectious Diseases in the Rambam Health Care campus and the "Brit Olam" nonprofit organization, offered a clinical clerkship in Kiboga hospital, Uganda. The elective took place in a public governmental hospital located in one of the poorest districts of Uganda. During a three-week period, the students accompanied by Israeli and Uganda tutors, participated in clinical rounds and other clinical activities in various departments of the hospital. This manuscript, describes the students' experiences in Kiboga. During the short elective, students had a unique opportunity to observe a different culture, immerse in a completely different healthcare system, learn about how a detailed medical history and a thorough physical examination can lead to diagnosis (without extensive diagnostic tests), and closely observe ethical challenges and difficult clinical decisions. The elective helped students develop personally and professionally and solidify their commitment to medicine. Currently, in Israeli medical schools, there are a few programs which expose students to medicine in low-resource countries. We believe that expanding the understanding of Global Health through courses and overseas opportunities in long-term partnerships, can improve the students' medical education.


Assuntos
Estágio Clínico , Educação Médica , Estudantes de Medicina , Currículo , Humanos , Faculdades de Medicina , Uganda
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...